Home > HR Series
| HR12120W |
| 12 V |
120.0w/cell |
| HR 12120W is designed specially for high efficient discharge application. It\'s characteristics are small volume, light weight and high discharge efficiency. It can be used for more than 260 cycles at 100% discharge in cycle service, or three to five years in standby service.
As with all CSB batteries, all are rechargeable, highly efficient, maintenance free, leak proof, useable in any position and ISO certified as well as recognized by UL. |
|
|
|
|
Specification |
|
| Capacity |
120W @ 15 minute-rate to 1.67V per cell
@ 25°C (77°F) |
| Weight |
Approx. 10.2 Kg (22.4 LBS) |
| Maximum Discharge Current
|
400A (5 Sec) |
| Internal Resistance Approx.
|
Approx. 9 mΩ |
| Operating Temperature
Range |
Discharge : -20°C~50°C ( -4°F~122°F)
Charge : 0°C~40°C (32°F~104°F)
Storage : -20°C~40°C ( -4°F~104°F) |
| Nominal Operating Temperature
Range |
25°C ± 3°C (77°F
± 5°F) |
| Float Charging Voltage
|
13.5 to 13.8 VDC/Unit Average at 25°C
(77°F) |
| Recommended Maximum Charging
current limit |
12.0 A |
| Equalization and Cycle
Service |
14.4 to 15.0 VDC/Unit Average at 25°C
(77°F) |
| Self Discharge |
CSB Batteries can be stored for more
than 6 months at 25°C (77°F). Please charge batteries
before using. For higher temperatures the time interval will
be shorter. |
| Terminal |
Thread Insert & Bolt |
| Container Material |
ABS (UL94-HB)*Flammability resistance
of UL94-V0 can be available upon request. |
Dimensions |
|

|
 |